AL-E1113 PLC TRAINER (OMRON)
Project Information
- Category: ROBOTICS AND MECHATRONICS
- Sub Category: PLC TRAINER
- Model Number: AL-E1113
Description
AL-E1113 PLC
TRAINER (OMRON)
BASIC PROGRAMMABLE
CONTROLLER (PLC) TRAINER – OMRON CP2E
Model: AL-E1113
Quantity: 1 Set
Offered Brand: AMBEYLABS
Application: Industrial Automation, PLC Programming
and Electrical Engineering Laboratory.
----------------------------------------------------------------------------------------------------------------------------------------------------------------1.
Product Overview
The Basic Programmable
Controller (PLC) Trainer is a complete industrial automation training platform
based on the Omron CP2E industrial-standard programmable logic controller. It
is designed to provide hands-on practical training in PLC programming, digital
input/output interfacing, ladder logic development, sequential control,
industrial switching applications, timers, counters and automation systems.
The trainer shall
incorporate 12 digital DC inputs and 8 relay outputs, USB and RS232C
communication interfaces, input simulation switches, output indication lamps,
LED status indicators, integrated 24 V DC power supply and standard 4 mm safety
connection sockets.
The complete trainer shall
be mounted on a robust industrial-grade metal panel with epoxy powder-coated
finish and aluminium-profile supporting structure. A separate desktop computer
workstation shall be provided on the right side, including monitor, keyboard,
mouse and CPU cabinet.
2. Detailed Technical
Specifications
A. PLC Controller Module
|
Parameter |
Specification |
|
Make |
Omron |
|
Series |
CP2E |
|
Controller Type |
Industrial PLC |
|
Digital Inputs |
12 Nos. |
|
Digital Outputs |
8 Nos. |
|
Output Type |
Relay |
|
Programming Capacity |
4K Steps |
|
Function Block Capacity |
4K Steps |
|
Data Memory |
4K Words |
|
USB Interface |
1 No. |
|
RS232C Interface |
1 No. |
|
High-Speed Counter |
2 Inputs at 100 kHz |
|
Additional Counter Inputs |
4 Inputs at 10 kHz |
|
CPU Status |
LED Indication |
|
Input/Output Status |
Individual LED Indication |
|
Programming Language |
Ladder Diagram |
B. Digital Input Module
- 12 digital input channels.
- Standard 4 mm banana connector
sockets.
- Individual LED indication for each
input.
- Three input common (COM) sockets.
- Twelve toggle switches for input
simulation.
- Provision for external digital input
connections.
- Clearly identified input channel
numbering.
- Suitable for studying digital
switching and logic operations.
C. Digital Output Module
- Eight digital relay output channels.
- Eight integrated output indication
lamps.
- Standard 4 mm connector sockets.
- Four output common (COM) sockets.
- Individual LED status indication.
- Provision for external output
connections.
- Suitable for relay-based industrial
control experiments.
D. Input Simulation
Module
- Twelve toggle switches.
- Individual ON/OFF operation.
- Direct interfacing with PLC digital
inputs.
- Clearly marked switch positions.
- Suitable for simulating industrial
switching signals.
E. I/O Mode Selector
Module
- MIX and EXTERNAL operating modes.
- Five selector switches.
- Provision for selecting internal
simulation and external connections.
- Clearly labelled selector positions.
- Suitable for different PLC I/O
configurations.
F. Integrated DC Power
Supply
- Output voltage: 24 V DC.
- Rated current: 5 A.
- Short-circuit protection.
- Fuse protection.
- DC power ON indication.
- Dedicated positive and negative
terminals.
- Suitable for PLC and experimental
circuit supply.
G. Power Supply
Distribution Module
- Three positive 24 V DC distribution
sockets.
- Three negative 24 V DC distribution
sockets.
- Standard 4 mm banana connectors.
- Clearly identified polarity.
- Suitable for external experimental
circuits.
H. Communication
Interface
- USB programming interface: 1 No.
- RS232C serial communication
interface: 1 No.
- USB communication with desktop
computer.
- PLC program downloading and
uploading.
- Online monitoring of input/output
conditions.
- USB programming cable supplied.
I. Main Power Supply
- Input supply: 240 V AC.
- Frequency: 50 Hz.
- Single-phase input.
- Main ON/OFF switch.
- Power ON indication lamp.
- Input fuse protection.
- Power cord connection.
- Proper earthing arrangement.
3. Desktop Computer
Specifications
The trainer shall be
supplied with a separate desktop computer workstation.
|
Parameter |
Minimum Requirement |
|
Processor |
Intel Core i5, 12th
Generation or newer |
|
Processor Cores |
10 Cores |
|
Processor Frequency |
Up to 4.40 GHz or higher |
|
RAM |
16 GB DDR4/DDR5 |
|
RAM Configuration |
1 × 16 GB |
|
Upgradeability |
Up to 32 GB |
|
Storage |
512 GB SSD |
|
Graphics |
Intel UHD or equivalent
integrated graphics |
|
Operating System |
Windows 11, 64-bit |
|
Monitor |
24-inch Full HD colour
monitor |
|
USB Ports |
Minimum 3 |
|
Display Interface |
HDMI |
|
Keyboard |
Standard keyboard |
|
Mouse |
Optical mouse |
4. PLC Programming
Software
Omron CX-Programmer /
CX-ONE
The system shall support
compatible Windows-based ladder diagram programming software.
Features:
- Ladder diagram creation and editing.
- PLC program development.
- Program downloading and uploading.
- Online monitoring.
- Timer and counter programming.
- Sequential control programming.
- Program debugging.
- PLC input/output status monitoring.
- USB communication with PLC.
- CX-Programmer / CX-ONE Trial/Demo
software supplied.
5. Mechanical
Construction
Industrial Aluminium
Profile Workstation
- Heavy-duty aluminium-profile
supporting frame.
- Robust metal front panel.
- Epoxy powder-coated finish.
- Industrial grey and silver colour
scheme.
- Blue reinforced corner connectors.
- Proper component mounting arrangement.
- Front-mounted control and connection
sections.
- Clearly printed component
identification.
- Proper internal wiring and cable
management.
- Separate right-side desktop computer
rack.
- Dedicated monitor and keyboard
platform.
- Separate CPU cabinet mounting arrangement.
- Suitable for tabletop laboratory
operation.
6. Experiments and
Training Applications
The system shall facilitate
the following experiments:
Basic PLC Experiments
- Study of PLC architecture and
hardware.
- Study of Omron CP2E PLC.
- Study of digital input and output
modules.
- Introduction to ladder diagram
programming.
- Implementation of AND, OR and NOT
logic gates.
- Normally open and normally closed
contacts.
- Internal relay operations.
- Latching and unlatching circuits.
- Timer ON-delay and OFF-delay
operations.
- Up-counter and down-counter
operations.
Industrial Automation
Experiments
- Motor START/STOP control using PLC.
- Forward and reverse motor control
logic.
- Electrical interlocking circuits.
- Traffic light control system.
- Conveyor belt automation.
- Sequential switching operations.
- Digital input/output interfacing.
- Relay output control.
- External switch interfacing.
- Automatic process sequence control.
Advanced PLC Experiments
- High-speed counter applications.
- Pulse counting and monitoring.
- USB-based PLC programming.
- RS232C serial communication.
- Online program monitoring.
- PLC program debugging.
- Fault identification and
troubleshooting.
- Industrial automation sequence
development.
7. Standard Scope of
Supply
|
Sr. No. |
Description |
Qty. |
|
1 |
Complete Basic PLC Trainer
with Omron CP2E PLC |
1 Set |
|
2 |
Desktop computer |
1 No. |
|
3 |
24-inch Full HD monitor |
1 No. |
|
4 |
Keyboard |
1 No. |
|
5 |
Optical mouse |
1 No. |
|
6 |
PLC operation/user manual |
1 No. |
|
7 |
Laboratory experiment
manual with answers |
1 No. |
|
8 |
Power cord cable |
1 No. |
|
9 |
Connecting leads |
1 Set |
|
10 |
Spare fuses |
2 Nos. |
|
11 |
USB programming cable |
1 No. |
|
12 |
CX-Programmer / CX-ONE
Trial/Demo software |
1 No. |
8. Safety Features
- Main input power ON/OFF switch.
- Input fuse protection.
- DC power supply short-circuit
protection.
- Proper electrical earthing.
- Insulated 4 mm connection sockets.
- LED indication for PLC input/output
status.
- Protected internal electrical wiring.
- Clearly labelled terminals.
- Proper cable management.
- Safe experimental connection
arrangement.
9. Warranty and
Documentation
- Three-year manufacturer's warranty.
- Complete operation and user manual.
- Laboratory experiment manual with
answers.
- PLC programming instructions.
- Desktop computer with Windows 11.
- USB programming cable.
- Necessary connecting accessories.
- Installation, commissioning and
demonstration.
- After-sales technical support.
10. Technical Summary
|
Particulars |
Offered Specification |
|
Brand |
AMBEYLABS |
|
Model Number |
AL-E1113 |
|
Product |
Basic Programmable
Controller PLC Trainer |
|
PLC Make |
Omron |
|
PLC Model |
CP2E |
|
Digital Inputs |
12 |
|
Relay Outputs |
8 |
|
Programming Capacity |
4K Steps |
|
Data Memory |
4K Words |
|
USB Communication |
1 Port |
|
RS232C Communication |
1 Port |
|
Input Simulation |
12 Toggle Switches |
|
Output Lamps |
8 |
|
Input COM |
3 |
|
Output COM |
4 |
|
I/O Selector |
5 Switches |
|
DC Supply |
24 V DC, 5 A |
|
Main Supply |
240 V AC, 50 Hz |
|
Software |
CX-Programmer / CX-ONE |
|
Desktop Processor |
Intel Core i5, 12th Gen or
newer |
|
RAM |
16 GB |
|
SSD |
512 GB |
|
Monitor |
24-inch Full HD |
|
Operating System |
Windows 11, 64-bit |
|
Construction |
Metal Panel with Aluminium
Profile |
|
Finish |
Epoxy Powder Coated |
|
Warranty |
3 Years |
11. General Tender
Requirements
- The complete system shall be supplied
in ready-to-operate condition.
- All components shall be properly
mounted and interconnected.
- All input and output terminals shall
be clearly identified.
- All connection sockets shall be
standard 4 mm type.
- The desktop computer shall be
compatible with the supplied PLC.
- All necessary connecting leads and
accessories shall be supplied.
- Complete practical manuals shall be
provided.
- The system shall be suitable for
engineering colleges, polytechnics, ITIs and industrial automation
laboratories.
Technical Note: The exact Omron CP2E CPU variant must be
confirmed against the specified I/O configuration, high-speed counter functions
and memory capacity before final tender submission. The CX-Programmer/CX-ONE
software is specified as Trial/Demo, not as a perpetual commercial licence.