DETAILED TECHNICAL SPECIFICATIONS

ELECTROMECHANICAL TRAINING SYSTEM

LOT 1 – ELECTRICAL ENGINEERING MACHINERY AND EQUIPMENT

Quantity: 1 Set                                                              

Tender Specification

Offered Brand: AMBEYLABS

Model No.: AL-E1399

Product Name: Electromechanical Training System

1. General Description

The Electromechanical Training System shall be an integrated, modular, workstation-based educational training system designed for conducting practical experiments and demonstrations in electrical engineering, electrical machines, power systems, and electrical measurements. The system shall facilitate hands-on study of DC power circuits, single-phase AC circuits, three-phase AC circuits, power factor correction, three-phase rotating machines, single-phase transformers, three-phase transformer banks, and permanent-magnet DC machines.

The complete system shall be supplied with a robust tabletop workstation, modular electrical control panels, electrical machines, measurement instruments, data acquisition and control interface, mobile storage cabinet, connecting leads, and all necessary safety accessories.

2. Detailed Technical Specifications

A. Workstation and Mechanical Structure

  1. Heavy-duty industrial-grade tabletop training workstation.
  2. Modular aluminium profile or equivalent rigid structural framework.
  3. Integrated electrical control panel with clearly identified functional modules.
  4. Ergonomically designed working surface for electrical machine experiments.
  5. Mobile storage cabinet with multiple compartments for storing accessories and instruments.
  6. Lockable storage facility with industrial-grade wheels and braking arrangement.
  7. Proper cable routing and management arrangement.
  8. All modules shall be suitably mounted and arranged for easy accessibility.
  9. The workstation shall have a professional finish with suitable electrical insulation and mechanical protection.

B. Electrical Power Supply Modules

The system shall include the following power supply modules:

  1. DC regulated power supply with adjustable output.
  2. Single-phase AC power supply module.
  3. Three-phase AC power supply module.
  4. Suitable voltage and current indication through digital meters.
  5. Individual ON/OFF control switches and protective arrangements.
  6. Overload and short-circuit protection.
  7. Clearly marked input, output, and measurement terminals.
  8. Proper electrical isolation and protection against accidental contact.

C. Three-Phase Induction Motor

  1. Type: Three-phase squirrel-cage induction motor.
  2. Number of poles: 4.
  3. Construction: Industrial-grade enclosed motor.
  4. Suitable for coupling with the dynamometer system.
  5. Three-phase electrical input terminals.
  6. Suitable for studying motor starting, speed, torque, power, and efficiency characteristics.
  7. Proper mounting arrangement on the workstation.

D. Synchronous Motor / Generator

  1. Type: Three-phase synchronous electrical machine.
  2. Operating mode: Motor and generator.
  3. Suitable for studying synchronous speed and load characteristics.
  4. Suitable excitation arrangement.
  5. Electrical terminals for stator and excitation connections.
  6. Suitable mechanical coupling with the dynamometer.
  7. Provision for studying synchronization and generator operation.

E. Permanent-Magnet DC Machine

  1. Type: Permanent-magnet DC motor / generator.
  2. Permanent-magnet field excitation.
  3. DC armature input/output terminals.
  4. Suitable for motor and generator operating experiments.
  5. Suitable for studying speed, torque, voltage, current, and efficiency characteristics.
  6. Mechanical coupling arrangement with the dynamometer system.

F. Single-Phase Transformer Module

  1. Type: Single-phase power transformer.
  2. Primary and secondary winding terminals.
  3. Suitable for studying transformer operation and characteristics.
  4. Provision for open-circuit and short-circuit tests.
  5. Suitable for studying voltage regulation and transformer efficiency.
  6. Clearly identified input and output terminals.

G. Three-Phase Transformer Components

  1. Three-phase transformer components with individual winding terminals.
  2. Suitable for studying three-phase transformer operation.
  3. Provision for primary and secondary winding connections.
  4. Suitable for studying phase relationships and transformation ratios.
  5. Suitable for practical demonstration of three-phase transformer connections.

H. Three-Phase Transformer Bank

  1. Modular transformer bank arrangement.
  2. Suitable for star-star, delta-delta, star-delta, and delta-star connections, as applicable to the supplied transformer configuration.
  3. Accessible winding terminals.
  4. Suitable for studying voltage, current, phase displacement, and transformer bank characteristics.
  5. Clearly marked connection terminals.

I. Resistive, Inductive and Capacitive Load Modules

  1. Resistive load module for studying resistive electrical circuits.
  2. Inductive load module for studying inductive circuit characteristics.
  3. Capacitive load module for studying capacitive circuit characteristics.
  4. Modular load connections.
  5. Suitable terminals for series and parallel connections.
  6. Provision for studying power factor and reactive power.
  7. Suitable protection against overload and accidental short circuits.

J. Power Factor Correction Module

  1. Modular power factor correction arrangement.
  2. Capacitive compensation facility.
  3. Suitable for demonstrating improvement of power factor in AC circuits.
  4. Suitable measurement points for voltage, current, and power factor.
  5. Provision for studying the effect of inductive and capacitive loads.

K. Synchronizing Module / Three-Phase Contactor

  1. Dedicated synchronization module.
  2. Three-phase contactor arrangement.
  3. Suitable control switches and indication lamps.
  4. Provision for studying synchronization of three-phase electrical machines.
  5. Suitable for demonstrating phase sequence, voltage matching, frequency matching, and synchronization principles.
  6. Appropriate electrical interlocking and protective arrangements.

L. Four-Quadrant Dynamometer / Power Supply

  1. Four-quadrant dynamometer system.
  2. Suitable for operating electrical machines in motoring and generating modes.
  3. Provision for measuring torque and rotational speed.
  4. Suitable for studying mechanical power and machine performance.
  5. Electronic control and power supply arrangement.
  6. Suitable mechanical coupling arrangement with the electrical machines.
  7. Digital indication and monitoring facility.

M. Data Acquisition and Control Interface

  1. Computer-compatible data acquisition and control interface.
  2. Suitable interface for monitoring electrical and mechanical parameters.
  3. Acquisition of voltage and current measurement signals.
  4. Monitoring of speed and torque parameters.
  5. Graphical display of measured parameters.
  6. Provision for recording and analysing experimental data.
  7. Suitable software for experiment monitoring and performance analysis.
  8. USB or equivalent communication interface.
  9. Suitable computer connectivity and control facility.

N. Digital Multimeter

  1. Digital multimeter for electrical measurements.
  2. AC and DC voltage measurement.
  3. AC and DC current measurement.
  4. Resistance measurement.
  5. Continuity testing facility.
  6. Suitable measurement leads and probes.

O. Lead-Acid Battery Pack

  1. Rechargeable lead-acid battery pack.
  2. Suitable DC voltage supply for the experiments.
  3. Proper battery terminals and connecting arrangement.
  4. Suitable mounting and storage arrangement.
  5. Protection against accidental short circuits.

P. Mechanical Accessories

  1. Timing belt for coupling electrical machines.
  2. Suitable belt-pulley arrangement.
  3. Mechanical mounting and alignment accessories.
  4. Machine coupling accessories.
  5. All required mechanical fixtures for conducting experiments.

Q. Connection Lead Set

  1. Complete set of electrical connecting leads.
  2. Flexible insulated connecting cables.
  3. Suitable safety connectors.
  4. Different colours for phase identification and DC polarity.
  5. Adequate quantity for all supplied experimental modules.
  6. Suitable current and voltage ratings for the respective circuits.

R. Safety Accessories

  1. Electrical isolation and protective arrangements.
  2. Overload and short-circuit protection.
  3. Emergency power isolation facility.
  4. Proper earthing arrangement.
  5. Insulated connecting terminals.
  6. Protective covers for rotating and moving components, wherever required.
  7. Safety labels and warning indications.
  8. All necessary interconnections and safety accessories.

3. Experiments / Training Capabilities

The system shall be capable of performing the following experiments:

  1. Study of DC electrical power circuits.
  2. Study of single-phase AC circuits.
  3. Study of three-phase AC circuits.
  4. Study of series and parallel R-L-C circuits.
  5. Study of power factor and power factor correction.
  6. Study of three-phase squirrel-cage induction motor characteristics.
  7. Study of synchronous motor operation.
  8. Study of synchronous generator characteristics.
  9. Study of permanent-magnet DC motor characteristics.
  10. Study of DC generator operation.
  11. Study of single-phase transformer characteristics.
  12. Open-circuit and short-circuit tests on transformers.
  13. Study of transformer voltage regulation and efficiency.
  14. Study of three-phase transformer connections.
  15. Study of three-phase transformer bank configurations.
  16. Study of synchronization of three-phase electrical machines.
  17. Study of torque-speed characteristics of electrical machines.
  18. Study of four-quadrant operation of electrical machines.
  19. Measurement of electrical and mechanical parameters.
  20. Computer-based data acquisition and performance analysis.

4. Standard Accessories and Deliverables

Sr. No.

Description

Quantity

1

Complete electromechanical training workstation

1 Set

2

Mobile storage cabinet

1 No.

3

DC, single-phase and three-phase power supplies

1 Set

4

Four-pole squirrel-cage induction motor

1 No.

5

Synchronous motor/generator

1 No.

6

Permanent-magnet DC machine

1 No.

7

Single-phase transformer module

1 Set

8

Three-phase transformer components

1 Set

9

Three-phase transformer bank

1 Set

10

R-L-C load modules

1 Set

11

Power factor correction module

1 No.

12

Synchronizing module and three-phase contactor

1 Set

13

Four-quadrant dynamometer/power supply

1 Set

14

Data acquisition and control interface

1 Set

15

Lead-acid battery pack

1 Set

16

Digital multimeter

1 No.

17

Timing belt and coupling accessories

1 Set

18

Electrical connecting lead set

1 Set

19

Safety accessories and interconnections

1 Set

20

Operating and experiment manuals

1 Set

5. General Requirements

  • The complete system shall be supplied in ready-to-use condition.
  • All modules shall be properly assembled, interconnected, and labelled.
  • All electrical machines shall be suitable for educational laboratory applications.
  • All necessary accessories required for conducting the specified experiments shall be included.
  • The system shall be supplied with detailed operating instructions and experiment manuals.
  • Installation, commissioning, and demonstration shall be provided.
  • The manufacturer shall provide warranty and after-sales technical support.

6. Offered Product Details

Particulars

Offered Details

Brand

AMBEYLABS

Model Number

AL-E1399

Product

Electromechanical Training System

Quantity

1 Set

Construction

Modular Workstation Type

Structure

Aluminium Profile / Industrial Frame

Power Supply

As per supplied configuration

Control

Modular Electrical Control Panel

Measurement

Digital Measurement System

Data Acquisition

Computer-Based Interface

Application

Electrical Engineering Laboratory

Note: Exact voltage, current, power, frequency, motor ratings, transformer ratings, dynamometer capacity, and software specifications should be entered in the final offered-value column according to the actual manufactured configuration. These ratings have not been assumed in this specification.

 