WhatsApp

AL-E1400 ADVANCED VFD VARIABLE FREQUENCY MOTOR DRIVE TRAINING SYSTEM

Project Information

  • Category: ROBOTICS AND MECHATRONICS
  • Sub Category: PLC TRAINER
  • Model Number: AL-E1400

Description

AL-E1400 ADVANCED VFD VARIABLE FREQUENCY MOTOR DRIVE TRAINING SYSTEM

DETAILED TECHNICAL SPECIFICATIONS

ADVANCED VFD VARIABLE FREQUENCY MOTOR DRIVE TRAINING SYSTEM

Model No.: AL-E1400

Quantity: 1 Set

Brand: AMBEYLABS

Product Series: Advanced Flex 5 Series VFD Training System

------------------------------------------------------------------------------------------------------------------------------------------

1. General Description

The Advanced VFD Variable Frequency Motor Drive Training System is a comprehensive educational workstation designed for practical training in industrial motor control, variable frequency drives, electrical drives, and industrial automation.

The system shall provide hands-on training in VFD configuration, programming, motor speed control, acceleration and deceleration control, analogue reference signal operation, relay-based control circuits, and three-phase induction motor operation.

The complete system shall consist of an industrial-grade variable frequency drive, industrial indication panel, ice cube control relays, START/STOP push buttons, selector switches, rheostat-based analogue control modules, three-phase Wye-wound induction motor, electrical connection terminals, and protective electrical components.

2. Detailed Technical Specifications

A. Variable Frequency Drive (VFD) Module

  1. Type: Industrial Variable Frequency Drive.
  2. Series: Flex 5 Series or equivalent.
  3. Suitable for controlling the speed of three-phase AC induction motors.
  4. Digital display for frequency and operating parameter indication.
  5. Keypad-based parameter setting and programming facility.
  6. Adjustable output frequency.
  7. Provision for motor START/STOP control.
  8. Adjustable acceleration and deceleration time.
  9. Forward and reverse motor operation, subject to drive configuration.
  10. Provision for external analogue speed reference.
  11. Built-in motor protection and fault monitoring.
  12. Suitable for demonstrating industrial variable-speed motor control.

B. Industrial Panel Indication Module

  1. Industrial-grade panel-mounted indication lamps.
  2. Red phase indication.
  3. Yellow phase indication.
  4. Blue phase indication.
  5. Green RUN indication.
  6. Amber FAULT indication.
  7. Clearly identified indicator labels.
  8. Suitable electrical connections for monitoring system operating status.

C. Ice Cube Control Relay Module

  1. Industrial plug-in type control relays.
  2. Suitable relay sockets and mounting arrangement.
  3. Electromechanical switching contacts.
  4. Clearly identified coil and contact terminals.
  5. Suitable for motor control and interlocking experiments.
  6. Provision for relay-based control circuit demonstrations.

D. Industrial START/STOP Control Module

  1. Industrial-grade START push button.
  2. Industrial-grade STOP push button.
  3. Suitable NO/NC contact arrangement.
  4. Panel-mounted control switches.
  5. Clearly identified push-button functions.
  6. Suitable for direct and VFD-based motor control experiments.

E. Selector Switch Module

  1. Industrial-grade rotary selector switches.
  2. Manual/Automatic selection facility.
  3. Forward/Off/Reverse selection facility, subject to VFD configuration.
  4. Multiple operating-position arrangement.
  5. Suitable electrical contact configuration.
  6. Clearly marked operating positions.

F. Rheostat-Based Analogue Speed Control Module

The system shall include analogue reference control facilities for demonstrating external VFD speed control.

  1. Adjustable 0–10 V DC control signal.
  2. Adjustable 5–20 mA control signal, as specified in the offered configuration.
  3. Separate control adjustment arrangements.
  4. Rotary adjustment knobs.
  5. Clearly identified signal terminals.
  6. Positive and negative connection terminals.
  7. Suitable for studying analogue speed reference control.
  8. Compatible with the supplied VFD analogue input configuration.

G. Three-Phase Wye-Wound Induction Motor

  1. Type: Three-phase AC squirrel-cage induction motor.
  2. Winding configuration: Wye (Star) wound.
  3. Suitable for operation with the supplied VFD.
  4. Industrial-grade motor construction.
  5. Accessible electrical connection arrangement.
  6. Suitable mounting base.
  7. Shaft-end protection arrangement.
  8. Suitable for studying motor speed and operating characteristics.
  9. Provision for practical demonstration of variable-frequency motor operation.

H. Electrical Input and VFD I/O Terminal Module

  1. Dedicated mains input connection.
  2. Main power ON/OFF switch.
  3. Separate VFD input/output connection terminals.
  4. Digital input terminals.
  5. Common terminal.
  6. Analogue input terminals.
  7. Analogue output terminals, where supported by the supplied drive.
  8. Clearly identified terminal markings.
  9. Insulated safety connection sockets.
  10. Proper electrical wiring and protection arrangements.

I. Circuit Diagram and Connection Panel

  1. Printed electrical circuit diagram.
  2. VFD input and output connection representation.
  3. Three-phase supply connection.
  4. Motor connection representation.
  5. Control signal identification.
  6. Suitable for teaching and troubleshooting exercises.

3. Mechanical Construction and Enclosure

Industrial Aluminium Profile Workstation

  1. Heavy-duty industrial aluminium profile structure.
  2. Silver-grey aluminium frame.
  3. Industrial grey front mounting panel.
  4. Blue reinforced corner connectors.
  5. Side-mounted carrying handles.
  6. Rigid and stable construction.
  7. Adjustable supporting feet.
  8. Properly secured electrical components.
  9. Professional industrial finish.
  10. Suitable for laboratory tabletop installation and transportation.

4. Experiments and Training Capabilities

The system shall facilitate the following experiments:

  1. Introduction to variable frequency drive technology.
  2. Study of VFD construction and operating principles.
  3. Study of VFD keypad and parameter programming.
  4. Starting and stopping of three-phase induction motors using VFD.
  5. Speed control of induction motors through frequency variation.
  6. Study of acceleration and deceleration control.
  7. Study of forward and reverse motor operation.
  8. Manual and automatic motor control.
  9. Study of industrial START/STOP control circuits.
  10. Study of ice cube relay operation.
  11. Study of industrial selector switches.
  12. Study of phase indication and RUN/FAULT status.
  13. Study of 0–10 V analogue speed reference control.
  14. Study of analogue current reference control.
  15. Study of motor speed response at different frequencies.
  16. Study of VFD fault indication and troubleshooting.
  17. Study of digital input and output control.
  18. Study of VFD and three-phase motor interfacing.
  19. Study of industrial motor control circuit diagrams.
  20. Demonstration of industrial variable-speed drive applications.

5. Standard Scope of Supply

Sr. No.

Description

Quantity

1

Complete Advanced VFD Training Workstation

1 Set

2

Flex 5 Series Variable Frequency Drive or equivalent

1 No.

3

Industrial panel indication module

1 Set

4

Ice cube control relays with sockets

1 Set

5

Industrial START push button

1 No.

6

Industrial STOP push button

1 No.

7

Manual/Automatic selector switch

1 No.

8

Forward/Off/Reverse selector switch

1 No.

9

0–10 V DC rheostat control module

1 No.

10

5–20 mA analogue control module

1 No.

11

Three-phase Wye-wound induction motor

1 No.

12

VFD I/O terminal module

1 Set

13

Electrical circuit diagram panel

1 No.

14

Electrical connecting leads

1 Set

15

Aluminium profile workstation structure

1 Set

16

Safety accessories and interconnections

1 Set

17

Operating and experiment manual

1 Set

6. Safety Features

  1. Main power ON/OFF switch.
  2. Suitable electrical isolation arrangement.
  3. Overload and short-circuit protection.
  4. Proper earthing arrangement.
  5. Insulated electrical terminals.
  6. Clearly marked input and output connections.
  7. Emergency power isolation facility.
  8. Suitable protection for motor shaft and rotating parts.
  9. Electrical warning labels and safety instructions.
  10. Proper cable routing and management.

7. General Requirements

  • Complete system shall be supplied in ready-to-use condition.
  • All electrical components shall be industrial-grade.
  • All modules shall be properly mounted and labelled.
  • The system shall include all required connecting leads and accessories.
  • All control functions shall be clearly identified.
  • Detailed operating and practical experiment manuals shall be provided.
  • Installation, commissioning, and demonstration shall be included.
  • Warranty and after-sales technical support shall be provided.

8. Offered Product Details

Particulars

Offered Specification

Brand

AMBEYLABS

Model Number

AL-E1400

Product Name

Advanced VFD Variable Frequency Motor Drive Training System

Series

Flex 5 Series or Equivalent

Quantity

1 Set

Drive Type

Variable Frequency Drive

Motor Type

Three-Phase AC Induction Motor

Motor Winding

Wye (Star)

Control System

Digital and Analogue

Analogue Voltage Reference

0–10 V DC

Analogue Current Reference

5–20 mA (as specified)

Control Components

Relays, Push Buttons, Selector Switches

Indication

Industrial Panel Indication

Construction

Aluminium Profile Workstation

Frame Colour

Industrial Grey / Silver

Corner Connectors

Blue

Application

Electrical Drives and Industrial Automation Laboratory

9. Technical Details to Be Confirmed in Final Manufacturing Configuration

The following values should be finalized according to the selected VFD and motor:

  • VFD input supply voltage and phase.
  • VFD output voltage and power rating.
  • VFD output frequency range.
  • Motor rated voltage, power, current and RPM.
  • Number of control relays and contact ratings.
  • Analogue current input compatibility (5–20 mA).
  • Digital input/output configuration.
  • Workstation overall dimensions.

Note: The specification retains the supplied 5–20 mA requirement. The analogue current signal range must be checked against the selected VFD; standard industrial drives commonly support 4–20 mA. All ratings should be verified against the actual manufacturer's datasheets before final tender submission.                                                              

Technical Details