AL-E317B NEGATIVE PHASE SEQUENCE RELAY (NUMERICAL)

Project Information

  • Category: ELECTRICAL ENGINEERING
  • Sub Category: ELECTRICAL ENGINEERING
  • Model Number: AL-E317B

Description

AL-E317B NEGATIVE PHASE SEQUENCE RELAY (NUMERICAL)

DETAILED TECHNICAL SPECIFICATIONS

NEGATIVE SEQUENCE RELAY (NUMERICAL TYPE)

Model No.: AL-E317B

Quantity: 1 Set

Offered Brand: AMBEYLABS

Product Category: Electrical Protection, Power System Protection and Numerical Relay Testing Equipment

-----------------------------------------------------------------------------------------------------------------------------------------------------

1. General Description

The Negative Sequence Relay (Numerical Type) is an advanced electrical engineering laboratory training system designed for studying negative sequence protection, phase unbalance detection, current transformer operation, and numerical protection techniques used in three-phase electrical power systems.

The system shall provide practical training in the measurement and analysis of three-phase electrical quantities, negative sequence current detection, transformer connections, current transformer characteristics, and numerical relay operation.

The complete system shall consist of a closed-panel construction with Hylam front sheet, miniature circuit breaker (MCB), phase indication lamps, three single-phase autotransformers, one three-phase star/star transformer, four current transformers, digital measuring instruments, numerical negative sequence relay, BTI terminals, and necessary electrical connections.

2. Detailed Technical Specifications

A. Main Control Panel and Enclosure

  1. Type: Closed electrical control panel.
  2. Front panel material: Hylam sheet.
  3. Overall dimensions: 600 mm (H) × 1200 mm (W) × 200 mm (D).
  4. Heavy-duty panel construction.
  5. Provision for mounting all electrical and measuring components.
  6. Properly identified control and measurement sections.
  7. Suitable mounting arrangement for transformers and current transformers.
  8. Proper cable routing and internal wiring.
  9. Clearly printed circuit diagram and component identification.
  10. Suitable for electrical engineering laboratory applications.

B. Main Input Supply and Protection Module

  1. Three-phase electrical supply arrangement.
  2. MCB-based input protection.
  3. Main power ON/OFF switching facility.
  4. R-Y-B phase indication lamps.
  5. Red indication for R phase.
  6. Yellow indication for Y phase.
  7. Blue indication for B phase.
  8. Properly identified input terminals.
  9. Suitable electrical isolation and protection arrangement.
  10. Proper earthing provision.

C. Single-Phase Autotransformer Module

  1. Type: Single-phase variable autotransformer.
  2. Quantity: 3 Nos.
  3. Current rating: 8 A each.
  4. Suitable for three-phase voltage adjustment and experimental supply arrangements.
  5. Variable output voltage adjustment facility.
  6. Rotary voltage control arrangement.
  7. Clearly identified input and output terminals.
  8. Suitable electrical insulation and protection.
  9. Proper mounting arrangement inside the panel.

D. Three-Phase Star/Star Transformer

  1. Type: Three-phase transformer.
  2. Winding configuration: Star/Star (Y/Y).
  3. Rated capacity: 1.5 kVA.
  4. Primary voltage: 400 V AC.
  5. Secondary voltage: 100 V AC.
  6. Suitable for three-phase voltage transformation experiments.
  7. Separate primary and secondary connection terminals.
  8. Clearly identified R-Y-B phase connections.
  9. Suitable for laboratory protection and measurement applications.

E. Current Transformer (CT) Module

  1. Type: Current Transformer.
  2. Quantity: 4 Nos.
  3. Primary current rating: 5 A.
  4. Secondary current rating: 1 A.
  5. Transformation ratio: 5/1 A.
  6. Suitable for current measurement and protection experiments.
  7. Properly identified primary and secondary terminals.
  8. Suitable mounting arrangement.
  9. Insulated connection terminals.
  10. Suitable for interfacing with numerical protection relays.

F. Numerical Negative Sequence Relay

  1. Type: Numerical Negative Sequence Protection Relay.
  2. Digital numerical protection arrangement.
  3. Suitable for detecting negative sequence current in three-phase electrical systems.
  4. Suitable for monitoring phase current imbalance.
  5. Digital display for relay parameters and measured values.
  6. Menu-based configuration and setting facility.
  7. Keypad-based parameter adjustment.
  8. Run indication.
  9. Trip indication.
  10. Alarm indication.
  11. Provision for relay trip output.
  12. Suitable for protection studies involving unbalanced three-phase conditions.
  13. Suitable for demonstrating negative sequence protection principles.

G. Digital Measurement Instruments

The system shall include digital measuring instruments for monitoring voltage and current parameters.

Digital AC Voltmeters

  • Quantity: 2 Nos.
  • Measurement range: 0–500 V AC.
  • Digital display with LED indication.
  • Suitable for monitoring AC voltage.
  • Clearly identified measurement terminals.

Digital AC Ammeters

  • Quantity: 4 Nos.
  • Measurement range: 0–10 A AC.
  • Digital display with LED indication.
  • Suitable for monitoring current in experimental circuits.
  • Suitable for interfacing with the supplied CT arrangement, as applicable.

H. BTI Terminal Module

  1. Quantity: 30 Nos.
  2. Type: BTI electrical connection terminals.
  3. Suitable for experimental circuit connections.
  4. Properly identified terminals.
  5. Suitable insulation and mounting arrangement.
  6. Provision for connecting transformers, CTs, relay inputs, and measuring instruments.
  7. Suitable for repeated laboratory connections.

3. Experiments and Training Capabilities

The system shall facilitate the following practical experiments:

  1. Study of three-phase electrical power systems.
  2. Study of negative sequence components in three-phase systems.
  3. Study of negative sequence relay construction and operation.
  4. Study of numerical protection relay features.
  5. Study of phase sequence and phase imbalance.
  6. Study of unbalanced three-phase voltage conditions.
  7. Study of unbalanced three-phase current conditions.
  8. Study of current transformer construction and working principles.
  9. Study of CT transformation ratio (5/1 A).
  10. Study of three-phase star/star transformer connections.
  11. Study of three-phase voltage transformation.
  12. Study of single-phase autotransformer operation.
  13. Study of adjustable three-phase experimental supply arrangements.
  14. Measurement of three-phase AC voltage.
  15. Measurement of current using current transformers.
  16. Study of negative sequence current measurement.
  17. Study of numerical relay parameter settings.
  18. Study of relay alarm and trip indications.
  19. Demonstration of negative sequence protection under unbalanced load conditions.
  20. Study of electrical protection schemes used in industrial power systems.

4. Standard Scope of Supply

Sr. No.

Description

Quantity

1

Complete Negative Sequence Relay Testing System

1 Set

2

Closed panel with Hylam front sheet

1 No.

3

Main MCB with phase indication lamps

1 Set

4

Single-phase autotransformers (8 A)

3 Nos.

5

Three-phase Star/Star transformer (1.5 kVA, 400/100 V)

1 No.

6

Current transformers (5/1 A)

4 Nos.

7

Numerical negative sequence protection relay

1 No.

8

Digital AC voltmeters (0–500 V AC)

2 Nos.

9

Digital AC ammeters (0–10 A AC)

4 Nos.

10

BTI connection terminals

30 Nos.

11

Internal electrical wiring and interconnections

1 Set

12

Circuit diagram and identification labels

1 Set

13

Necessary electrical safety accessories

1 Set

14

Operating and experiment manual

1 No.

5. Safety Features

  1. MCB-based electrical input protection.
  2. Main power ON/OFF switching facility.
  3. R-Y-B phase indication.
  4. Proper electrical earthing.
  5. Insulated electrical connection terminals.
  6. Proper internal wiring and cable management.
  7. Suitable protection for transformer and autotransformer circuits.
  8. Clearly identified electrical connections.
  9. Protection against accidental contact with live components.
  10. Suitable warning labels and operating instructions.

6. General Requirements

  • Complete system shall be supplied in ready-to-operate condition.
  • All electrical components shall be properly mounted inside the closed panel.
  • All instruments and terminals shall be clearly labelled.
  • All internal wiring shall be properly terminated.
  • Necessary interconnections and accessories shall be supplied.
  • Detailed operating instructions and practical experiment manuals shall be provided.
  • Installation, commissioning, and demonstration shall be included.
  • Warranty and after-sales technical support shall be provided.

7. Offered Product Details

Particulars

Offered Specification

Brand

AMBEYLABS

Model Number

AL-E317B

Product Name

Negative Sequence Relay (Numerical Type)

Quantity

1 Set

Panel Type

Closed Panel

Front Panel

Hylam Sheet

Dimensions

600 × 1200 × 200 mm (H × W × D)

Autotransformers

3 × Single Phase, 8 A

Main Transformer

Three-Phase Star/Star

Transformer Rating

1.5 kVA

Transformer Voltage

400/100 V

Current Transformers

4 Nos.

CT Ratio

5/1 A

Numerical Relay

Negative Sequence Relay

Digital AC Voltmeters

2 × 500 V AC

Digital AC Ammeters

4 × 10 A AC

BTI Terminals

30 Nos.

Application

Electrical Power System Protection Laboratory

8. Important Technical Clarifications

For final manufacturing and tender compliance, the following details should be confirmed:

  1. Input supply voltage and frequency.
  2. Output voltage range of the three single-phase autotransformers.
  3. Exact numerical relay manufacturer, model and protection functions.
  4. Negative sequence current pickup and operating-time settings.
  5. CT primary and secondary connection arrangements.
  6. Digital meter accuracy class and display specifications.
  7. Whether the 30 BTI terminals are 4 mm safety terminals.
  8. Transformer vector group and insulation class.

Note: The above specifications are prepared using the supplied equipment description. Unspecified electrical ratings and relay settings have not been assumed. All component ratings should be verified against the actual offered configuration before final tender submission.