AL-E317B NEGATIVE PHASE SEQUENCE RELAY (NUMERICAL)
Project Information
- Category: ELECTRICAL ENGINEERING
- Sub Category: ELECTRICAL ENGINEERING
- Model Number: AL-E317B
Description
AL-E317B NEGATIVE
PHASE SEQUENCE RELAY (NUMERICAL)
NEGATIVE SEQUENCE RELAY (NUMERICAL TYPE)
Model No.: AL-E317B
Quantity: 1 Set
Offered Brand:
AMBEYLABS
Product Category: Electrical
Protection, Power System Protection and Numerical Relay Testing Equipment
-----------------------------------------------------------------------------------------------------------------------------------------------------
1. General
Description
The Negative Sequence Relay (Numerical Type) is an
advanced electrical engineering laboratory training system designed for
studying negative sequence protection, phase unbalance detection, current
transformer operation, and numerical protection techniques used in three-phase
electrical power systems.
The system shall provide practical training in the
measurement and analysis of three-phase electrical quantities, negative
sequence current detection, transformer connections, current transformer
characteristics, and numerical relay operation.
The complete system shall consist of a closed-panel
construction with Hylam front sheet, miniature circuit breaker (MCB), phase
indication lamps, three single-phase autotransformers, one three-phase
star/star transformer, four current transformers, digital measuring
instruments, numerical negative sequence relay, BTI terminals, and necessary
electrical connections.
2. Detailed
Technical Specifications
A. Main Control Panel and Enclosure
- Type: Closed electrical control panel.
- Front panel material: Hylam sheet.
- Overall dimensions: 600 mm (H) × 1200 mm (W) × 200 mm (D).
- Heavy-duty panel construction.
- Provision for mounting all electrical and measuring components.
- Properly identified control and measurement sections.
- Suitable mounting arrangement for transformers and current
transformers.
- Proper cable routing and internal wiring.
- Clearly printed circuit diagram and component identification.
- Suitable for electrical engineering laboratory applications.
B. Main Input Supply and Protection Module
- Three-phase electrical supply arrangement.
- MCB-based input protection.
- Main power ON/OFF switching facility.
- R-Y-B phase indication lamps.
- Red indication for R phase.
- Yellow indication for Y phase.
- Blue indication for B phase.
- Properly identified input terminals.
- Suitable electrical isolation and protection arrangement.
- Proper earthing provision.
C. Single-Phase Autotransformer Module
- Type: Single-phase variable autotransformer.
- Quantity: 3 Nos.
- Current rating: 8 A each.
- Suitable for three-phase voltage adjustment and experimental
supply arrangements.
- Variable output voltage adjustment facility.
- Rotary voltage control arrangement.
- Clearly identified input and output terminals.
- Suitable electrical insulation and protection.
- Proper mounting arrangement inside the panel.
D. Three-Phase Star/Star Transformer
- Type: Three-phase transformer.
- Winding configuration: Star/Star (Y/Y).
- Rated capacity: 1.5 kVA.
- Primary voltage: 400 V AC.
- Secondary voltage: 100 V AC.
- Suitable for three-phase voltage transformation experiments.
- Separate primary and secondary connection terminals.
- Clearly identified R-Y-B phase connections.
- Suitable for laboratory protection and measurement applications.
E. Current Transformer (CT) Module
- Type: Current Transformer.
- Quantity: 4 Nos.
- Primary current rating: 5 A.
- Secondary current rating: 1 A.
- Transformation ratio: 5/1 A.
- Suitable for current measurement and protection experiments.
- Properly identified primary and secondary terminals.
- Suitable mounting arrangement.
- Insulated connection terminals.
- Suitable for interfacing with numerical protection relays.
F. Numerical Negative Sequence Relay
- Type: Numerical Negative Sequence Protection Relay.
- Digital numerical protection arrangement.
- Suitable for detecting negative sequence current in three-phase
electrical systems.
- Suitable for monitoring phase current imbalance.
- Digital display for relay parameters and measured values.
- Menu-based configuration and setting facility.
- Keypad-based parameter adjustment.
- Run indication.
- Trip indication.
- Alarm indication.
- Provision for relay trip output.
- Suitable for protection studies involving unbalanced three-phase
conditions.
- Suitable for demonstrating negative sequence protection
principles.
G. Digital Measurement Instruments
The system shall include digital measuring instruments for
monitoring voltage and current parameters.
Digital AC Voltmeters
- Quantity: 2 Nos.
- Measurement range: 0–500 V AC.
- Digital display with LED indication.
- Suitable for monitoring AC voltage.
- Clearly identified measurement terminals.
Digital AC Ammeters
- Quantity: 4 Nos.
- Measurement range: 0–10 A AC.
- Digital display with LED indication.
- Suitable for monitoring current in experimental circuits.
- Suitable for interfacing with the supplied CT arrangement, as
applicable.
H. BTI Terminal Module
- Quantity: 30 Nos.
- Type: BTI electrical connection terminals.
- Suitable for experimental circuit connections.
- Properly identified terminals.
- Suitable insulation and mounting arrangement.
- Provision for connecting transformers, CTs, relay inputs, and
measuring instruments.
- Suitable for repeated laboratory connections.
3. Experiments and
Training Capabilities
The system shall facilitate the following practical
experiments:
- Study of three-phase electrical power systems.
- Study of negative sequence components in three-phase systems.
- Study of negative sequence relay construction and operation.
- Study of numerical protection relay features.
- Study of phase sequence and phase imbalance.
- Study of unbalanced three-phase voltage conditions.
- Study of unbalanced three-phase current conditions.
- Study of current transformer construction and working principles.
- Study of CT transformation ratio (5/1 A).
- Study of three-phase star/star transformer connections.
- Study of three-phase voltage transformation.
- Study of single-phase autotransformer operation.
- Study of adjustable three-phase experimental supply arrangements.
- Measurement of three-phase AC voltage.
- Measurement of current using current transformers.
- Study of negative sequence current measurement.
- Study of numerical relay parameter settings.
- Study of relay alarm and trip indications.
- Demonstration of negative sequence protection under unbalanced
load conditions.
- Study of electrical protection schemes used in industrial power
systems.
4. Standard Scope
of Supply
|
Sr. No. |
Description |
Quantity |
|
1 |
Complete Negative Sequence Relay Testing System |
1 Set |
|
2 |
Closed panel with Hylam front sheet |
1 No. |
|
3 |
Main MCB with phase indication lamps |
1 Set |
|
4 |
Single-phase autotransformers (8 A) |
3 Nos. |
|
5 |
Three-phase Star/Star transformer (1.5 kVA, 400/100 V) |
1 No. |
|
6 |
Current transformers (5/1 A) |
4 Nos. |
|
7 |
Numerical negative sequence protection relay |
1 No. |
|
8 |
Digital AC voltmeters (0–500 V AC) |
2 Nos. |
|
9 |
Digital AC ammeters (0–10 A AC) |
4 Nos. |
|
10 |
BTI connection terminals |
30 Nos. |
|
11 |
Internal electrical wiring and interconnections |
1 Set |
|
12 |
Circuit diagram and identification labels |
1 Set |
|
13 |
Necessary electrical safety accessories |
1 Set |
|
14 |
Operating and experiment manual |
1 No. |
5. Safety Features
- MCB-based electrical input protection.
- Main power ON/OFF switching facility.
- R-Y-B phase indication.
- Proper electrical earthing.
- Insulated electrical connection terminals.
- Proper internal wiring and cable management.
- Suitable protection for transformer and autotransformer circuits.
- Clearly identified electrical connections.
- Protection against accidental contact with live components.
- Suitable warning labels and operating instructions.
6. General
Requirements
- Complete system shall be supplied in ready-to-operate condition.
- All electrical components shall be properly mounted inside the
closed panel.
- All instruments and terminals shall be clearly labelled.
- All internal wiring shall be properly terminated.
- Necessary interconnections and accessories shall be supplied.
- Detailed operating instructions and practical experiment manuals
shall be provided.
- Installation, commissioning, and demonstration shall be included.
- Warranty and after-sales technical support shall be provided.
7. Offered Product
Details
|
Particulars |
Offered Specification |
|
Brand |
AMBEYLABS |
|
Model Number |
AL-E317B |
|
Product Name |
Negative Sequence Relay (Numerical Type) |
|
Quantity |
1 Set |
|
Panel Type |
Closed Panel |
|
Front Panel |
Hylam Sheet |
|
Dimensions |
600 × 1200 × 200 mm (H × W × D) |
|
Autotransformers |
3 × Single Phase, 8 A |
|
Main Transformer |
Three-Phase Star/Star |
|
Transformer Rating |
1.5 kVA |
|
Transformer Voltage |
400/100 V |
|
Current Transformers |
4 Nos. |
|
CT Ratio |
5/1 A |
|
Numerical Relay |
Negative Sequence Relay |
|
Digital AC Voltmeters |
2 × 500 V AC |
|
Digital AC Ammeters |
4 × 10 A AC |
|
BTI Terminals |
30 Nos. |
|
Application |
Electrical Power System Protection Laboratory |
8. Important
Technical Clarifications
For final manufacturing and tender compliance, the
following details should be confirmed:
- Input supply voltage and frequency.
- Output voltage range of the three single-phase autotransformers.
- Exact numerical relay manufacturer, model and protection
functions.
- Negative sequence current pickup and operating-time settings.
- CT primary and secondary connection arrangements.
- Digital meter accuracy class and display specifications.
- Whether the 30 BTI terminals are 4 mm safety terminals.
- Transformer vector group and insulation class.
Note: The above
specifications are prepared using the supplied equipment description.
Unspecified electrical ratings and relay settings have not been assumed. All
component ratings should be verified against the actual offered configuration
before final tender submission.