AL-E319C OVER CURRENT RELAY TRAINER (ELECTROMECHANICAL TYPE)
Project Information
- Category: ELECTRICAL ENGINEERING
- Sub Category: POWER SYSTEM AND PROTECTION LAB
- Model Number: AL-E319C
Description
AL-E319C OVER
CURRENT RELAY TRAINER (ELECTROMECHANICAL TYPE)
AL-E319C OVER CURRENT RELAY TRAINER (ELECTROMECHANICAL
TYPE)
1. Product
Overview
The AL-E319C Over Current Relay Trainer
(Electromechanical Type) is a laboratory training system designed for the
practical study of over-current relay protection systems. The trainer
incorporates a single-phase AC supply section, digital AC measurement, an
electromechanical over-current relay circuit, timer controls, trip/alarm
indication and controllable load-current facilities.
2. Scope of
Learning
The trainer is designed for:
- Study of Over Current Relay Protection System.
- Demonstration of relay operation under
over-current conditions.
- Study of tripping and reset operation.
- Observation of load current and voltage during
protection experiments.
- Study of alarm and trip indication.
3. Technical
Specifications
A. Power Supply
|
Parameter |
Specification |
|
AC Power Supply |
0–230 V, 2 A |
|
Mains Supply |
230 V AC |
|
Frequency |
50 Hz |
|
Mains Tolerance |
+10% |
|
Supply Type |
Single-phase |
B. Single-Phase
Power Supply Module
The trainer shall incorporate a dedicated Single-Phase
Power Supply Module (230 V, 50 Hz).
Features
- MCB protection.
- Emergency-stop facility.
- Red power indicator.
- Clearly identified supply terminals.
- Suitable protection for laboratory operation.
4. Digital AC
Meter Module
A dedicated digital measurement module shall be
provided.
Digital AC Voltmeter
- Digital AC voltage measurement.
- Panel-mounted display.
- Suitable input terminals for experimental
measurement.
Digital AC Ammeter
- Digital AC current measurement.
- Panel-mounted display.
- Suitable for monitoring load current.
Note: The
supplied specification does not state the exact measurement ranges or accuracy
of the digital meters.
5. Over-Current
Relay Module
The main protection section shall contain the circuit
required for studying an over-current relay protection system.
Integrated Features
- Circuit for over-current relay.
- Trip indicators.
- Timer reset switch.
- Buzzer indicator for alarm.
- Push ON/OFF control for load current.
- Control switches for timer and load current.
- 4 A autotransformer for voltage control.
The arrangement shall allow the user to apply and
control the experimental load current and observe relay operation, trip
indication and alarm response.
6. Relay
Control & Indication
The trainer shall provide the following control and
indication facilities:
|
Feature |
Provision |
|
Over-current relay circuit |
Provided |
|
Trip indication |
Provided |
|
Timer reset |
Reset switch provided |
|
Alarm |
Buzzer indicator |
|
Load-current control |
Push ON/OFF |
|
Timer control |
Control switch |
|
Load-current ON control |
Control switch |
|
Voltage control |
4 A autotransformer |
7. Safety &
Protection Features
The trainer shall incorporate:
- MCB-based short-circuit protection.
- Emergency-stop facility.
- High-voltage test points.
- 4 mm safety sockets.
- Insulated front-panel construction.
- Clearly printed circuits and symbols.
- Modular enclosed construction.
- Accessible and clearly identified connection
points.
8. Mechanical
Construction
The trainer shall be housed in a:
- Modular rack-type aluminium extruded metal
cabinet.
- Robust laboratory-grade enclosure.
- Front-panel-mounted electrical components.
- Clearly printed circuit diagrams and symbols.
- Suitable construction for repeated educational
laboratory use.
Approximate Size
42" × 16"
9. Front Panel
The front panel shall accommodate:
- Single-phase power supply section.
- MCB.
- Emergency-stop.
- Red supply indicator.
- Digital AC voltmeter.
- Digital AC ammeter.
- Electromechanical over-current relay section.
- Trip indicators.
- Timer controls.
- Timer reset.
- Alarm buzzer.
- Load-current ON/OFF control.
- 4 A autotransformer voltage-control section.
- Safety test points and patch-cord connections.
10.
Interconnection Accessories
The trainer shall be supplied with:
- 4 mm heavy-duty patch cords.
- Patch-cord length: 1 metre.
- 4 mm safety sockets for high-voltage test points.
11. Salient
Features
- Electromechanical over-current relay trainer.
- Practical study of over-current protection.
- 0–230 V, 2 A AC supply.
- Single-phase 230 V, 50 Hz supply module.
- MCB protection.
- Emergency-stop facility.
- Red power indication.
- Digital AC voltmeter.
- Digital AC ammeter.
- Over-current relay circuit.
- Trip indication.
- Timer reset facility.
- Buzzer alarm indication.
- Load-current ON/OFF control.
- Timer and load-current control switches.
- 4 A autotransformer for voltage control.
- High-voltage test points with 4 mm safety
sockets.
- Heavy-duty 4 mm patch cords.
- Modular aluminium extruded rack-type cabinet.
- Approximate dimensions: 42" × 16".
- Instruction manual supplied.
12. Packing
List
|
Sr. No. |
Item |
Quantity |
|
1 |
AL-E319C Over Current Protection Relay Trainer |
1 Set |
|
2 |
Patch Cords |
1 Set |
|
3 |
Rheostat |
100 Ω, 5 A |
|
4 |
Filament Lamp |
1 Unit |
13. Optional
Accessories
No optional accessorie0073.
Tender-Ready Summary
AL-E319C
shall be a complete electromechanical over-current relay protection training
system with a 0–230 V, 2 A AC supply, 230 V/50 Hz single-phase power
module, MCB and emergency stop, digital AC voltmeter and ammeter, over-current
relay circuit, trip indicators, timer reset, buzzer alarm, load-current
control, timer controls and 4 A autotransformer voltage control. The complete
trainer shall be housed in a modular aluminium extruded metal rack cabinet of
approximately 42" × 16", with 4 mm safety sockets, heavy-duty
patch cords and instruction manual.