WhatsApp

AL-E544B DOMESTIC HOUSE WIRING CONTROL TRAINER

Project Information

  • Category: ELECTRICAL ENGINEERING
  • Sub Category: ELECTRICAL ENGINEERING
  • Model Number: AL-E544B

Description

AL-E544B DOMESTIC HOUSE WIRING CONTROL TRAINER

AL-E544B DOMESTIC HOUSE WIRING CONTROL TRAINER

1. Product Overview

The AL-E544B Domestic House Wiring Control Trainer is a practical laboratory training system designed for studying and demonstrating domestic house wiring, including single-phase energy measurement, switching, protection, distribution, socket connections, lighting controls, fan regulation and staircase switching.

The trainer provides a modular rack-mounted arrangement with domestic wiring components and dedicated house-wiring control boxes for practical experiments.

2. Scope of Learning

The trainer is designed for:

·        Study of domestic house wiring.

·        Study of single-phase electrical distribution.

·        Study of domestic energy-meter connections.

·        Study of single-phase switching.

·        Study of cartridge-fuse protection.

·        Study of two-way/staircase switching.

·        Study of distribution through a single-phase isolator.

·        Study of power switch and socket connections.

·        Study of domestic lamp control.

·        Study of ceiling-rose connections.

·        Study of fan regulator operation.

·        Study of indicator connections.

·        Study of emergency-stop protection.

·        Practical wiring using 4 mm safety patch cords.

3. Electrical Supply

Parameter

Specification

Supply Type

Single-phase AC mains

Rated Voltage

230 V AC

Frequency

50 Hz

Mains Tolerance

+10%

Application

Domestic wiring experiments

4. Main Components Mounted on Panel

4.1 Single-Phase Energy Meter

·        Single-phase energy meter provided on the trainer.

·        Used for demonstrating domestic electrical energy measurement.

·        Integrated into the domestic distribution circuit.

4.2 Single-Phase Switch

·        Panel-mounted single-phase switch.

·        Used for controlling the domestic supply circuit.

4.3 Cartridge Fuses

·        2 Nos. cartridge fuses.

·        Provided for circuit protection.

·        Enables practical study of fuse-based protection.

4.4 Staircase Switch / Two-Way Switch

·        Two-way switching arrangement.

·        Suitable for demonstrating control of a lighting load from two locations.

·        Useful for staircase-light wiring experiments.

4.5 Single-Phase Isolator

·        Distribution line provided through a single-phase isolator.

·        Allows isolation of the downstream domestic wiring circuit.

4.6 Power Switch and Socket Pair

·        Domestic power switch and socket arrangement.

·        Suitable for studying connection of electrical loads to a domestic supply.

4.7 Emergency Stop

·        Emergency-stop facility provided on the trainer.

·        Enables rapid disconnection of the experimental supply in an emergency.

5. HOUSE WIRING CONTROL BOXES

The trainer includes 2 Nos. House Wiring Control Boxes.

Each House Wiring Control Box Includes:

Sl. No.

Component

Quantity

1

Electronics Blast*

1 No.

2

5-Pin Socket

1 No.

3

Switches

3 Nos.

4

Fan Regulator

1 No.

5

Ceiling Rose

1 No.

6

Indicator

1 No.

7

Lamp Holder

1 No.

*The supplied specification uses the term “Electronics Blast”; it has been retained as provided.

6. House Wiring Control Box – Functional Facilities

The control boxes provide practical facilities for studying:

·        Domestic switch connections.

·        Socket wiring.

·        Fan-regulator connections.

·        Ceiling-rose wiring.

·        Lamp-holder connections.

·        Indicator wiring.

·        Multi-point switching.

·        Domestic electrical-load connections.

7. Front Panel Construction

·        Front panel manufactured using high-class insulated Bakelite sheet.

·        Circuit diagrams and symbols are provided through a well-printed sticker/graphic layout.

·        Components and terminals are clearly identified.

·        Wiring circuits are arranged for easy observation and practical training.

·        Suitable for repeated laboratory use.

8. Mechanical Construction

Parameter

Specification

Cabinet Type

Modular rack type

Frame

Aluminium extruded metal cabinet

Enclosure

Metal cabinet

Front Panel

Insulated Bakelite sheet

Approx. Trainer Size

36" × 24"

Mounting

Modular rack-based construction

9. Connection System

·        4 mm heavy-duty patch cords supplied.

·        High-voltage test points provided through 4 mm safety sockets.

·        Clearly identified connection points.

·        Suitable for repeated connection/disconnection during practical experiments.

·        Colour-coded/identified terminals facilitate safe experimental wiring.

10. Protection Features

Emergency Protection

·        Built-in emergency stop facility.

·        Provides rapid shutdown of the trainer supply.

Short-Circuit Protection

MCB-based short-circuit protection.

·        Protects the experimental circuit against excessive current conditions.

Fuse Protection

·        Two cartridge fuses are incorporated into the domestic wiring system.

11. Salient Features

·        Designed specifically for domestic house-wiring training.

·        Single-phase 230 V AC operation.

·        Integrated single-phase energy meter.

·        Two-way/staircase switching facility.

·        Cartridge-fuse protection.

·        Single-phase isolator.

·        Power switch and socket pair.

·        Emergency-stop facility.

·        2 Nos. house-wiring control boxes.

·        Fan regulator.

·        Ceiling rose.

·        Lamp holder.

·        Indicator.

·        5-pin socket.

·        Multiple switches.

·        High-voltage 4 mm safety sockets.

·        Heavy-duty 4 mm patch cords.

·        Insulated Bakelite front panel.

·        Modular aluminium-extrusion rack.

·        MCB short-circuit protection.

·        Instruction manual supplied.

·        Compact 36" × 24" training setup.

12. Standard Accessories

1.      AL-E544B Domestic House Wiring Control Trainer

2.      2 Nos. House Wiring Control Boxes

3.      4 mm Heavy-Duty Patch Cords

4.      Instruction Manual

5.      Required built-in protection devices

13. Optional Accessories

None specified in the supplied specification.

14. Model Identification

Model No.: AL-E544B
Product Name: Domestic House Wiring Control Trainer
Application: Domestic Electrical Wiring & Installation Training
Supply: 230 V AC, 50 Hz, +10%
Approx. Size: 36" × 24"
Construction: Modular rack-type aluminium extruded metal cabinet with insulated Bakelite front panel.

Size of the trainer set 36”x24”

OPTIONAL ACCESSORIES:

·   No

Technical Details